Controlled atmosphere for the long-term storage of fruit and vegetables – featuring our own gas-tight CA doors, in-house design and installation, and documented leak-tightness. Gas-tight storage rooms have been our speciality since 1966 – from Germany’s first gas-tight fruit store right up to the present day.

since 1966gas-tight fruit storage facilities
40+Years of service as a goalkeeper
1–10Months of apple storage

Leading companies place their trust in Plattenhardt + Wirth

ALDI South
ALDI Nord
Hofer
EDEKA
Count Palatine
Milei
Vetter Pharma
Galliker
Goldsteig
Wiesenhof
Nestlé
Mifroma
Borgmeier Frischgeflügel logo
Customer logo Logo_UlmerFleisch_farbig
Rügenwalder Mühle
kellermann logo – persönlich frisch
Your extra touch of freshness

Months of harvest quality – thanks to a controlled atmosphere

CA storage (short for ‘controlled atmosphere’) refers to a storage technique used for the long-term storage of pome fruit such as apples or pears. Natural ripening begins after harvest – with state-of-the-art technology and a high-quality CA storage facility, this process is reduced to a minimum. Quality, colour, flavour, texture and quantity are preserved, whilst losses in both quantity and quality are prevented.

  • CA, ULO & DCA stores: Gas-tight storage rooms with controlled atmosphere – from a single room to a complete storage facility.
  • In-house gas-tight CA doors: Based on the principle of static contact pressure – in use for over 40 years and deliberately designed for low maintenance.
  • Dispatch stores & sorting rooms: Individually planned around your operating processes – for the period between removal from storage and delivery.
  • Tightness tested & documented: Every room is verifiably accepted by pressure test – the basis of all CA storage.
Airtight lift gates in a range of colours – space-saving for long-term storage

CA/ULO Bearing Brochure

A concise overview of processes, gate systems, storage conditions and references, ready to share. (PDF, 1,3 MB)

Download PDF
What is included in your CA stock?

Components for your gas-tight storage facility

Rooms for CA, ULO and DCA

Gas-tight storage facilities for every process – tailored to fruit type, variety and marketing.

In-house CA gateways

Gates based on the principle of static contact force – deliberately designed with few components requiring maintenance.

Gas-tight building envelope

Sandwich panels and waterproofing from a single source – installed by our own specialist fitters.

Pressure test per room

Every storage room is inspected by means of a pressure test, and the results are documented.

Stock control warehouses & sorting areas

Tailored to the period between removal from stock and dispatch.

Ceiling window for visual inspection

It is forbidden to enter a CA warehouse whilst it is in operation – skylights provide a view of the goods in storage.

Why Plattenhardt + Wirth

Why is Plattenhardt + Wirth the right partner for CA-Lager?

Plattenhardt + Wirth built Germany’s first gas-tight fruit storage facility in 1966 – gas-tight CA/ULO storage facilities have been our speciality for decades. We offer a one-stop service, from planning right through to documented leak testing.

60+A family-run business since 1965

Innovation, hard work and courage – now in its second generation, with over 60 years’ project experience.

5.000+completed projects

From individual cold stores to turnkey facilities with production, cold storage and office space.

12Locations in Germany and Austria

Local presence and rapid response times – both in project work and in our service provision. We also operate in Switzerland.

250+Staff within the network

Our own planning, installation and service teams – a single point of contact for your project.

Your route to the new CA warehouse

Four steps to a finished project

A dedicated point of contact will guide you through every stage – from your initial enquiry right through to well beyond handover.

  1. Enquiry

    Tell us about your project – via the form, by telephone or by email. We’ll get back to you as soon as possible and discuss the initial questions regarding fruit varieties, stock and capacity targets.

    Free of charge
  2. Offer

    You will receive a transparent quote setting out clear services, deadlines and responsibilities.

    An overview of all trades
  3. Design

    Detailed planning and installation carried out by our own specialist fitters – completed in time for the harvest; modifications to existing installations by arrangement with the customer.

    1 contact person
  4. Service & Maintenance

    Handover with a documented leak test – followed by maintenance, inspections and spare parts all from the same supplier.

    Quick & easy
Step 1 is free of charge

Start with a no-obligation enquiry

Tell us about your project – new build, extension or conversion of existing facilities. And even after handover, we remain your point of contact:

  • Maintenance
  • Leak tests
  • Spare parts for doors & gates
Key facts

Understanding CA storage: methods, conditions, operation

Only storage with consistently low levels of oxygen and carbon dioxide is designed to ensure that you can continue to offer fresh produce even after several months. Our in-house gas-tight CA doors operate on the tried-and-tested principle of static contact pressure and ensure the safe CA storage of your products. We would also be happy to design your distribution warehouse and sorting areas to your specific requirements – installed by our own specialist fitters, with robust, long-lasting quality down to the last detail and a deliberate avoidance of components prone to maintenance issues.

CA, ULO or DCA – which is right for my business?

CA storage regulates oxygen and carbon dioxide levels in airtight chambers, thereby slowing down the ripening process. ULO storage maintains oxygen levels just above the biological minimum – for maximum shelf life. The DCA storage system dynamically adjusts the atmosphere, enabling even longer storage times whilst maintaining consistent quality. We can advise you on which method is best suited to the fruit type, variety and marketing strategy.

Typical storage conditions in the CA warehouse

During fruit storage, low temperatures of −1 to 6 °C (depending on the fruit and variety), high humidity of 90 to 95 per cent, a low oxygen content of usually 2 to 3 per cent and an elevated carbon dioxide content of 2 to 5 per cent.

What are the key considerations when it comes to storage?

The optimal harvest date determines the quality of storage. The storage facility should be filled as quickly as possible – ideally within a week – and the fruit should be stacked in a well-ventilated manner. The oxygen content should only be reduced once the fruit has reached its final temperature; in the case of mixed varieties, the requirements of the most sensitive variety apply.

Safety: Never enter the CA warehouse whilst it is in operation

Under no circumstances should you enter a CA storage area whilst it is in operation – this also applies to ULO and DCA storage areas. The oxygen content is well below the breathable range. Even after operations have ceased, sufficient ventilation must be ensured before entering.

Operate cost-effectively and energy-efficiently

Efficiency starts with the planning stage: good insulation, energy-efficient refrigeration technology and an optimal layout. During operation, key factors include rapid, cool storage, keeping door opening times as short as possible, unobstructed air circulation, regular maintenance and calibrated measuring equipment. LED lighting and a solar panel system for self-consumption can further reduce energy consumption.

Gates: the heart of gas-tightness

Our in-house CA doors operate on the tried-and-tested principle of static contact pressure – deliberately designed with as few maintenance-prone components as possible. Doors that have been in use for over 40 years and are still functioning today are proof of their durability and efficiency. The airtightness of each room is verified and documented by means of a pressure test.

Frequently Asked Questions

FAQ on CA, ULO and DCA warehouses

What is a CA warehouse?

A CA (controlled atmosphere) storage facility is a gas-tight cold store designed for the long-term storage of fruit and vegetables. In addition to temperature and humidity, the composition of the air – in particular the oxygen and carbon dioxide levels – is also precisely controlled. This significantly slows down the natural ripening process and preserves the quality, colour, flavour and texture.

What distinguishes ULO and DCA warehouses from CA warehouses?

The ULO (Ultra Low Oxygen) storage system maintains the oxygen level at just above the minimum biological threshold, thereby minimising the ripening process. The DCA (Dynamic Controlled Atmosphere) storage system dynamically adjusts the oxygen and carbon dioxide levels – for even longer storage times whilst maintaining consistent quality.

How long can I store fruit in CA storage facilities?

Shelf life depends on the type and variety of fruit. Long-term storage is particularly common for pome fruit: depending on the variety, apples can be stored for between 1 and 10 months without any significant loss of quantity or quality – and this period can be extended further using ULO or DCA technology.

What are the conditions like in a CA camp?

 

  • low temperature (−1 to 6 °C, depending on the fruit and variety)
  • high humidity (90–95 %)
  • low oxygen content (usually 2–3 %)
  • increased carbon dioxide levels (2–5 per cent, depending on the fruit and variety)

Am I allowed to enter a CA warehouse?

Under no circumstances should you enter a CA storage facility whilst it is in operation – this also applies to ULO and DCA storage facilities! Even after such a facility has ceased operation, sufficient ventilation must be ensured before entering.

How can I run my CA warehouse cost-effectively?

Key factors include energy-efficient design of refrigeration systems and insulation, rapid storage in a cool environment, keeping door opening times to a minimum, unobstructed air circulation, regular maintenance and well-sealed rooms. Energy-saving LED lighting and a solar panel system for self-consumption can also be worthwhile – we’d be happy to assist with assessment and implementation.