Cold store constructionFlammkuchen-Profi frozen food warehouse
New cold store for Flammkuchen-Profi: approx. 2,150 pallet spaces over 2,000 m², mobile racking and structural fire protection without a sprinkler system.
View project →














Premises with a high fire load pose a significant risk to operators and property insurers. As a rule, property insurers therefore require preventative fire protection – which can often only be implemented sensibly and cost-effectively by reducing the oxygen content in the ambient air. Our construction method creates the appropriate conditions for the cost-effective, continuous operation of the technical system that maintains the atmosphere required to prevent fires.

Cold store constructionNew cold store for Flammkuchen-Profi: approx. 2,150 pallet spaces over 2,000 m², mobile racking and structural fire protection without a sprinkler system.
View project →
Industrial & Commercial ConstructionJust under 5,000 m² of production and storage space – a combination of refurbishment of existing buildings and new technical construction, carried out as a main contractor.
View project →
Industrial & Commercial ConstructionConstruction of the new EURONICS specialist store in Radeberg. The project involved the creation of modern retail, office and lounge areas. The adjacent existing buildings remained in use throughout the construction work.
View project →Gas-tight construction has been our core competence for decades: from Germany’s first gas-tight fruit storage facility in 1966, through CA, ULO and DCA storage facilities, to enclosures for inerting – offering everything from consultancy to maintenance under one roof.
Innovation, hard work and courage – now in its second generation, with over 60 years’ project experience.
From individual cold stores to turnkey facilities with production, cold storage and office space.
Local presence and rapid response times – both in project work and in our service provision. We also operate in Switzerland.
Our own planning, installation and service teams – a single point of contact for your project.
A dedicated contact person will guide you through every stage – from your initial enquiry right through to well beyond the installation.
Tell us about your project – we’ll assess the fire load, the goods in storage, the property insurer’s requirements and the structural conditions.
You will receive a transparent quotation setting out clear services, deadlines and responsibilities – tailored to the inerting technology.
Enclosures, doors and penetrations installed by our own specialist fitters – followed by an airtightness test using the blower-door method.
Handover with documentation – after that, we remain your point of contact, for example for leak tests and repairs.
Tell us about your project – new build, extension or retrofit of existing facilities. And even after installation, we remain your point of contact:
To this end, we use high-quality, building-regulations-approved sandwich panels – multi-layered, robust and durable, predominantly non-combustible and designed to comply with the applicable standards and regulations. Whether it’s the complete enclosure of a high-bay warehouse or a smaller storage facility: the solution is tailored to your project and integrates seamlessly into your existing infrastructure. Airtightness is verified using the blower-door test method once the project is complete.
Rooms with a high fire load pose a significant risk to operators and insurers. The required preventive fire protection can often only be implemented sensibly and cost-effectively by reducing the oxygen content – this prevents the fire from starting in the first place, rather than having to be extinguished.
The inerting system maintains the low-oxygen atmosphere on a permanent basis. The more airtight the building envelope, the less the system has to work – our construction method creates the conditions necessary for this cost-effective, continuous operation.
Airtightness lies in the details: connection brackets manufactured specifically for this purpose, joint sealing systems and tightly integrated doors and penetrations combine individual panels to form an airtight envelope.
Once the project is complete, the building’s airtightness is verified using the blower-door test – providing reliable evidence for you and your property insurer.
Healthy people can access the facility at any time: the oxygen content in the low-oxygen atmosphere is comparable to that experienced whilst in the mountains.
We use high-quality sandwich panels approved by the building authorities – multi-layered, robust, durable and predominantly non-combustible, designed to comply with the applicable standards and regulations.
Inerting is a preventative fire safety measure that involves reducing the oxygen content: the oxygen content in the ambient air is lowered to such an extent that a fire cannot start in the first place – rather than having to extinguish it in an emergency. This requires a gas-tight building envelope.
Using connection brackets and joint sealing systems manufactured specifically for this purpose, we create highly airtight and therefore cost-effective spaces. This is verified after project completion using the so-called blower-door test.
Yes, healthy people can access it at any time. The oxygen content in the air is comparable to that found in the mountains.
The walls and ceilings are predominantly constructed from non-combustible sandwich panels. We use only high-quality panels that have been approved by the building authorities, and which are designed in accordance with the applicable standards and regulations.
Whether it’s a new build, an extension or retrofitting an existing property: tell us about your project – we’ll get back to you as soon as possible.
Get in touch now